Biological Filter: Cartridge Gas Filter: Filter 01: Filter 02: Filter 03: Filter 04: Filter 05: Filter 06: Fixed Bed Air Filter: Fixed Bed Liquid Filter: Gas Filter: HEPA Gas Filter: High Efficiency Filter: High Pass Filter: IonExchange Filter: Liquid Filter: LowPass Filter: Mideffect Filter: Mode Filter: Mode Filter Indication: Oxygen Enriched Filter: Press Filter: Roll Air Filter
Filtration
· Fichier PDF
Side Stream Filtration for Cooling Towers Side stream filtration systems continuously filter a portion of the cooling water to remove suspended solids, organics, and silt particles, reducing the likelihood of fouling and biological growth, which in turn helps to control other issues in the system such as scaling and corrosion,
Continuous Backwash Filters for Sidestream Filtration
· Fichier PDF
Side Stream Filtration Guidelines Sidestream Filter Installation email: info@quantrol,net 9001 Hanslik Court Naperville, IL 60564 Phone: 866-782-6876 Fax: 630,355,3568
· Nalco Pretreatment Solutions PTS manufactures the UltraSand Plus High Efficiency Filters HEF Side Stream Filtration Systems to remove suspended solids from open or closed recirculating cooling systems, The ability to remove extremely fine particles is the key to successful cooling water filtration, The unique design of the side stream filter provides 0,5 or 0,25 micron particle removal with minimal backwash …
Side Stream Filtration Guidelines
Side Stream Filter for Water Treatment
Closed Loop Side Stream Filtration
· Fichier PDF
Why we Need Sidestream Filtration? DynaSand®Filter Cooling towers make excellent air scrubbers/ washers Accumulate dirt grit sand and chemical residues Solids can clog cooling tower spray nozzles and reduce operating efficiency heat transfer Critical in the Middle East during sand storms
Sidestream Filtration for CHW, LTHW & MTHW
Figure 2 Cooling Tower with Side Stream Filtration Examples Technology Characterization Side stream filtration systems continu-ously filter a portion of cooling water to remove debris and particles Filtered water is then pumped back into the main condenser line through a nozzle or re-turned to the cooling tower basin called the sump Figure 2 below shows a sim-
Side Stream Filtration for Cooling Towers
· Fichier PDF
Side Stream Filtration
Filter input and return lines should be at least 10 feet apart to avoid registering the same water Sump/basin sidesteam filtration removes filters and returns clean water directly to the tower sump This is the system of choice since it allows use of sweeper jets to direct sediment to the filter inlet to keep the basin free from debris Today all three
This allows the side stream filter to remove the solids from the water as it passes through the filter itself, Side stream filters can also manage known issues involving the build-up of particles in evaporative cooling towers, Having a side stream filter installed in a cooling tower can help to prolong the lifespan of a cooling tower system, maintain heat transfer efficiencies and keep the tower running more efficiently, with less downtime,
The Importance of Side Stream Filtration in Water and
· Fichier PDF
Side Stream Filtration in Closed Systems
Sidestream filters work by filtering a small percentage of full flow 5 – 15% so that the complete system volume is filtered 2 – 3 times every 24 hours, Sidestream filters provide an excellent solution for filtering high volumes of CHW and LTHW or MTHW, It must be noted that filtration combined with water treatment is part of a …
SIDE STREAM FILTERS DSF15 / DSF50 The DSF Side Stream Filters are specially designed to remove troublesome suspended debris from re-circulating water systems, such as heating circuits, chilled water or condensate systems, The filters incorporate easily changed highly efficient re-usable bags and offer a low cost but extremely effective remedy for removing corrosion products and accumulated
Side Stream Filter Sizing •Method 1 –System Flow Rate •System Flow x 10% = recommended housing flow rate •Example, 120 GPM X 10% = 12 GPM •Choose a filter housing flow rate => 12 GPM
Side stream filter piping diagram
side stream filter piping diagram
Side Stream Filter Backwash, Our side stream filtration unit continuously and progressively cleans the heated or chilled water systems as water flows through, This is also referred to as a side stream filter backwash, Different pressure can easily be measured across the sidestream filter bag to determine the water flow rates and gauge the filtration rates accordingly, This helps to determine
P&ID Symbols for Filters » The Piping Engineering World
Side stream filtration systems continuously filter a portion of the cooling water to remove suspended solids, organics, and silt particles, reducing the likelihood of fouling and biological growth, which in turn helps to control other issues in the system such as scaling and corrosion,
Taille du fichier : 1MB
Technical Evaluation of Side Stream Filtration for Cooling
· Fichier PDF